Gas Tight Syringe for Manual Use / °¡½º »ùÇà ÅõÀÔ¿ë ÁÖ»ç±â, SS Plunger
ÁÖ¿äƯ¡
¡á ÁÖ¿ëµµ : Sample Dosage for Gas Chromatography, HPLC Valve, Autosampler |
Cat. No. | Model | ¿ë·® | Plunger Type | Needle | |
---|---|---|---|---|---|
od (Gauge) | ±æÀÌ | ||||
S14-165-401 | 3030205 | 5 ul | SS | 0.47 mm (G26S) | 51 mm |
S14-165-405 | 3030206 | 10 ul | |||
S14-165-409 | 3030207 | 25 ull | 0.72 mm (G22S) | ||
S14-165-413 | 3030208 | 50 ul | |||
S14-165-417 | 3030209 | 100 ul | |||
S14-165-421 | 3030210 | 250 ul | 0.72 mm (G22) |
Cat. No. | Model | ¿ë·® | Plunger Type | Needle | |
---|---|---|---|---|---|
od (Gauge) | ±æÀÌ | ||||
S14-165-451 | 3030389 | 5 ul | SS | 0.47 mm (G26S) | 51 mm |
S14-165-455 | 3030298 | 10 ul | |||
S14-165-459 | 3030299 | 25 ull | 0.72 mm (G22S) | ||
S14-165-463 | 3030300 | 50 ul | |||
S14-165-467 | 3030301 | 100 ul | |||
S14-165-471 | 3030302 | 250 ul | 0.72 mm (G22) | ||
S14-165-475 | 3030303 | 500 ul |
Cat. No. | Model | ¿ë·® | Needle | |
---|---|---|---|---|
od (Gauge) | ±æÀÌ | |||
S14-165-901 | 3050072 | 5 ul | 0.47 mm (G26S) | 51 mm |
S14-165-905 | 3050022 | 10 ul | ||
S14-165-909 | 3050179 | 25 ull ~ 10 mll | 0.72 mm (G22) | |
S14-165-913 | 3050036 | 0.72 mm (G22S) |
Fixed Needle Type | ||||||
---|---|---|---|---|---|---|
Cat. No | Model | Description | Unit | Price(VATº°µµ) | Àç°í/³³±â | ºñ°í |
S14-165-401 | 3030205 |  Gas Tight Syringe Fixed Needle type 5ul 0.47 mm(G26S) | 1/EA | ¼ÒºñÀÚ°¡ : 41,400¿ø |
2 | °ü½É |
S14-165-405 | 3030206 |  Gas Tight Syringe Fixed Needle type 10ul 0.47 mm(G26S) | 1/EA | ¼ÒºñÀÚ°¡ : 35,500¿ø |
30 Day | °ü½É |
S14-165-409 | 3030207 |  Gas Tight Syringe Fixed Needle type 25ul 0.72 mm(G22S) | 1/EA | ¼ÒºñÀÚ°¡ : 43,500¿ø |
2 | °ü½É |
S14-165-413 | 3030208 |  Gas Tight Syringe Fixed Needle type 50ul 0.72 mm(G22S) | 1/EA | ¼ÒºñÀÚ°¡ : 41,400¿ø |
2 | °ü½É |
S14-165-417 | 3030209 |  Gas Tight Syringe Fixed Needle type 100ul 0.72 mm(G22S) | 1/EA | ¼ÒºñÀÚ°¡ : 49,400¿ø |
2 | °ü½É |
S14-165-421 | 3030210 |  Gas Tight Syringe Fixed Needle type 250ul 0.72 mm(G22) | 1/EA | ¼ÒºñÀÚ°¡ : 53,300¿ø |
30 Day | °ü½É |
Removable Needle Type | ||||||
Cat. No | Model | Description | Unit | Price(VATº°µµ) | Àç°í/³³±â | ºñ°í |
S14-165-451 | 3030389 |  Gas Tight Syringe Removable Needle type 5ul 0.47 mm(G26S) | 1/EA | ¼ÒºñÀÚ°¡ : 67,100¿ø |
2 | °ü½É |
S14-165-455 | 3030298 |  Gas Tight Syringe Removable Needle type 10ul 0.47 mm(G26S) | 1/EA | ¼ÒºñÀÚ°¡ : 57,300¿ø |
1 | °ü½É |
S14-165-459 | 3030299 |  Gas Tight Syringe Removable Needle type 25ul 0.72 mm(G22S) | 1/EA | ¼ÒºñÀÚ°¡ : 49,400¿ø |
3 | °ü½É |
S14-165-463 | 3030300 |  Gas Tight Syringe Removable Needle type 50ul 0.72 mm(G22S) | 1/EA | ¼ÒºñÀÚ°¡ : 61,200¿ø |
3 | °ü½É |
S14-165-467 | 3030301 |  Gas Tight Syringe Removable Needle type 100ul 0.72 mm(G22S) | 1/EA | ¼ÒºñÀÚ°¡ : 67,100¿ø |
3 | °ü½É |
S14-165-471 | 3030302 |  Gas Tight Syringe Removable Needle type 250ul 0.72 mm(G22) | 1/EA | ¼ÒºñÀÚ°¡ : 71,200¿ø |
30 Day | °ü½É |
S14-165-475 | 3030303 |  Gas Tight Syringe Removable Needle type 500ul 0.72 mm(G22) | 1/EA | ¼ÒºñÀÚ°¡ : 71,200¿ø |
30 Day | °ü½É |
Replacement Needle | ||||||
Cat. No | Model | Description | Unit | Price(VATº°µµ) | Àç°í/³³±â | ºñ°í |
S14-165-901 | 3050072 |  Spare Needle 5ul ¿ë 0.47 mm(G26S) | 3/PK | ¼ÒºñÀÚ°¡ : 44,700¿ø |
30 Day | °ü½É |
S14-165-905 | 3050022 |  Spare Needle 10ul ¿ë 0.47 mm(G26S) | 3/PK | ¼ÒºñÀÚ°¡ : 31,700¿ø |
30 Day | °ü½É |
S14-165-909 | 3050179 |  Spare Needle 25 ull ~10 ml ¿ë 0.72 mm (G22) | 3/PK | ¼ÒºñÀÚ°¡ : 31,700¿ø |
30 Day | °ü½É |
S14-165-913 | 3050036 |  Spare Needle 25 ull ~10 ml ¿ë 0.72 mm (G22S) | 3/PK | ¼ÒºñÀÚ°¡ : 31,700¿ø |
30 Day | °ü½É |