Osmometer 3000 Series/»ïÅõ¾Ð ÃøÁ¤±â
ÁÖ¿äƯ¡
¡á Freezing Point (ºùÁ¡ ¹æ½Ä) Osmoneter |
Cat. No | Model | Description |
---|---|---|
O04-78-101 | 3000 Basic | ±âº»Çü, Comunication ±â´É ¹× Option ÀåÂø ºÒ°¡ |
O04-78-105 | 3000 Standard | Comunication, No Printer |
O04-78-109 | 3000 D | ³»ÀåÇÁ¸°ÅÍ |
Cat. No. | O04-78-101 | O04-78-105 | O04-78-109 |
---|---|---|---|
Model | 3000 Basic | 3000 Standard | 3000 D |
Display | 5.7" LCD - Touch Screen | ||
Cryst. Process | By means of the tip of a stainless steel needle covered with ice crystals which is controlled automatically | ||
Cooling | By means of two separate peltier cooling systems with heat dissipation by air | ||
Lower Cooling System | Electronic temperature regulation, deviation < ¡¾0.1 ¡É | ||
Test Time | 60 Seconds | ||
Sample Volume | 50 µl (Single Sample) | ||
Resoluion | 1 mOsmol/kg H2O | ||
Range | 0 up to 3000 mOsmol/kg H2O | ||
Reproducibility | ¡Â ¡¾2 digit [0.. 400] mOsmol/kg H2O ¡Â ¡¾0.5 % [400.. 1500] mOsmol/kg H2O ¡Â ¡¾1.0 % [1500.. 3000] mOsmol/kg H2O |
||
Linearity | Less than ¡¾1% in calibrated range | ||
Output Port | X | DTE RS232, USB | |
Ambient Temp. | 10 ¡É to 35 ¡É | ||
Power supply | 100-240 V, 50/60 Hz, 80 VA | ||
Dimension | w205 ¡¿ d220 ¡¿ h360 mm | ||
Weight | Approx. 6.4kg | Printer | ºÒ°¡ | ³»Àå |
Cat. No | Model | »ïÅõ¾Ð ³óµµ(mOsmol/kg) | Ampul |
---|---|---|---|
O04-78-955 | 30.9.0100 | 100 | 10 ampul |
O04-78-959 | 30.9.0290 | 290 | |
O04-78-963 | 30.9.0020 | 300 | |
O04-78-967 | 30.9.0500 | 500 | |
O04-78-971 | 30.9.0850 | 850 | |
O04-78-975 | 30.9.2000 | 2000 |
Cat. No | Model | Description |
---|---|---|
O04-78-911 | 32.02 | Micro Sample Volume 15 ul |
O04-78-915 | 32.03 | Barcode Reader |
O04-78-990 | 30.9.0010 | Measuring Vessels for Osmomat 3000 |
O04-78-993 | 30.9.1020 | Ink ribbon cassette (gonotec) |
O04-78-995 | 30.9.1010 | Printer Paper |
O04-78-999 | 35.9.1030 | Cleaning Paper |
Sample Volume 15ul (32.02) Reproducibility : ¡Â ¡¾2.0% [0 .... 3000] mOsmol/kg
Cat. No | Model | Description | Unit | Price(VATº°µµ) | Àç°í/³³±â | ºñ°í |
---|---|---|---|---|---|---|
O04-78-101 | 3000 Basic |  Osmometer ±âº»Çü Comunication ±â´É ¹× Option ÀåÂø ºÒ°¡ | 1/EA | ¼ÒºñÀÚ°¡ : 9,500,000¿ø |
30 Day | °ü½É |
O04-78-105 | 3000 Standard |  Osmometer Standard Comunication ±â´É ¹× Option ÀåÂø ºÒ°¡ | 1/EA | ¼ÒºñÀÚ°¡ : 10,375,000¿ø |
30 Day | °ü½É |
O04-78-109 | 3000 D |  Osmometer Standard ³»ÀåÇÁ¸°ÅÍ | 1/EA | ¼ÒºñÀÚ°¡ : 11,750,000¿ø |
30 Day | °ü½É |
Standard Solution | ||||||
Cat. No | Model | Description | Unit | Price(VATº°µµ) | Àç°í/³³±â | ºñ°í |
O04-78-955 | 30.9.0100 |  Calibration standard 100 mOsmol/kg 10 ampul | 1/EA | ¼ÒºñÀÚ°¡ : 102,000¿ø |
30 Day | °ü½É |
O04-78-959 | 30.9.0290 |  Calibration standard 290 mOsmol/kg 10 ampul | 1/EA | ¼ÒºñÀÚ°¡ : 106,900¿ø |
30 Day | °ü½É |
O04-78-963 | 30.9.0020 |  Calibration standard 300 mOsmol/kg 10 ampul | 1/EA | ¼ÒºñÀÚ°¡ : 105,500¿ø |
30 Day | °ü½É |
O04-78-967 | 30.9.0500 |  Calibration standard 500 mOsmol/kg 10 ampul | 1/EA | ¼ÒºñÀÚ°¡ : 102,000¿ø |
30 Day | °ü½É |
O04-78-971 | 30.9.0850 |  Calibration standard 850 mOsmol/kg 10 ampul | 1/EA | ¼ÒºñÀÚ°¡ : 112,000¿ø |
30 Day | °ü½É |
O04-78-975 | 30.9.2000 |  Calibration standard 2000 mOsmol/kg 10 ampul | 1/EA | ¼ÒºñÀÚ°¡ : 112,000¿ø |
30 Day | °ü½É |
Accessory | ||||||
Cat. No | Model | Description | Unit | Price(VATº°µµ) | Àç°í/³³±â | ºñ°í |
O04-78-911 | 32.02 |  Micro Sample Volume 15 ul ±¸¸Å½Ã ±âº»¼ÂÆà º¯°æ Option | 1/EA | ¹®ÀÇ |
30 Day | °ü½É |
O04-78-915 | 32.03 |  Barcode Reader | 1/EA | ¼ÒºñÀÚ°¡ : 1,100,000¿ø |
30 Day | °ü½É |
O04-78-990 | 30.9.0010 |  Measuring Vessels for Osmomat 3000 | 1000/PK | ¼ÒºñÀÚ°¡ : 262,200¿ø |
30 Day | °ü½É |
O04-78-993 | 30.9.1020 |  Ink ribbon cassette (gonotec) | 1/EA | ¼ÒºñÀÚ°¡ : 45,000¿ø |
6 | °ü½É |
O04-78-995 | 30.9.1010 |  Printer Paper | 8/PK | ¼ÒºñÀÚ°¡ : 99,000¿ø |
4 | °ü½É |
O04-78-999 | 35.9.1030 |  Cleaning Paper | 1/EA | ¼ÒºñÀÚ°¡ : 139,300¿ø |
30 Day | °ü½É |