Low Temp. Circulating Water Bath, - 40¡É / ¼øÈ¯½Ä Àú¿Â Ç׿ ¼öÁ¶, - 40¡É
ÁÖ¿äÆ¯Â¡
¡á °·ÂÇÑ ¼øÈ¯ ÆßÇÁ¸¦ ÀÌ¿ëÇÏ¿© ¿ÜºÎ±â±â¿Í ¿¬°áÇÏ¿© »ç¿ëÇϱ⿡ ¾Ë¸ÂÀ½ |
|
| Cat. No | Model | ¿ë·® | Temp. Range |
|---|---|---|---|
| B04-91-510 | LC-LT408 | 8 L | -40¡É ~ +150¡É |
| B04-91-520 | LC-LT412 | 12 L | |
| B04-91-530 | LC-LT422 | 22 L | |
| B04-91-540 | LC-LT430 | 30 L |
| Cat. No | Model | Description |
|---|---|---|
| B04-91-992 | VA-LCWB100 | ualification IQ, OQ for Low Temp. Circulating Water Bath |
| B04-91-892 | VA-LCWB200 | Qualification PQ for Low Temp. Circulating Water Bath |
| Cat. No | Model | Description |
|---|---|---|
| B04-01-085 | LI-USB | RS485 to USB Communication Cable |
| B04-91-483 | ET101M | External Sensor, Pt100, ¨ª4¡¿L300 mm |
| Cat. No. | B04-91-510 | B04-91-520 | B04-91-530 | B04-91-540 | ||
|---|---|---|---|---|---|---|
| Model | LC-LT408 | LC-LT412 | LC-LT422 | LC-LT430 | ||
| Capacity | 8 L | 12 L | 22 L | 30 L | ||
| Controller | Control | PID Control, Auto-tuning | ||||
| Display | GLCD (Graphic LCD) | |||||
| Resolution | 0.01¡É | |||||
| Timer | Run start / Wait start (99 hr 59 min) | |||||
| Temperature | Range | -40¡É to +150¡É | ||||
| Cooling Range | -40 ~ 40¡É( 40¡É ÀÌÇÏ¿¡¼ºÎÅÍ ³Ã°¢ÀåÄ¡ ±¸µ¿) | |||||
| Accuracy at 0¡É | ¡¾0.3¡É | |||||
| Uniformity at 0¡É | ¡¾0.12¡É | ¡¾0.21¡É | ¡¾0.28¡É | ¡¾0.36¡É | ||
| Pump | Capacity | 22 L/min (at water 25¡É) | ||||
| Pressure | 0.47 bar / 6.8 psi (at water 25¡É) | |||||
| Size | Internal | w170¡¿d320¡¿h150 mm | w250¡¿d320¡¿h150 mm | w300¡¿d370¡¿h200 mm | w300¡¿d460¡¿h220 mm | |
| External | w330¡¿d440¡¿h710 mm | w330¡¿d440¡¿h725 mm | w440¡¿d510¡¿h835 mm | w460¡¿d600¡¿h920 mm | ||
| Top Open | w170¡¿d145 mm | w250¡¿d145 mm | w300¡¿d190 mm | w300¡¿d290 mm | ||
| Weight | 35kg | 41kg | 55kg | 66kg | ||
| Material | Interior | 304 Stainless Steel | ||||
| Exterior | Powder Coated Steel | |||||
| Electric Supply |
Power | 1 Phase / 220VAC / 50/60 Hz | ||||
| Max Consumption | 1.5 kW (6.8 A) | 2 kW (9.1 A) | 2.5 kW (11.4 A) | 3 kW (13.7 A) | ||
| Power Line | Standard Plug | |||||
| Other | Drain | 1/4¡± Hose Nipple male | ||||
| Circulating IN / OUT | 1/2¡± Stainless Steel Tubing | |||||
| Caster | Leveling Caster | |||||
| Safety | Over Temp. & Current Protection, Automatical Fault Sensing System | |||||
| Cat. No | Model | Description | Unit | Price(VATº°µµ) | Àç°í/³³±â | ºñ°í |
|---|---|---|---|---|---|---|
| B04-91-510 | LC-LT408 |  Low Temp. Bath Circulating 8L, -40¡É ¡Ú ¹è¼Ûºñ º°µµ Á¦Ç°ÀÔ´Ï´Ù. |
1/EA | ¼ÒºñÀÚ°¡ : 2,840,100¿ø |
3 | °ü½É |
| B04-91-520 | LC-LT412 |  Low Temp. Bath Circulating 12L, -40¡É ¡Ú ¹è¼Ûºñ º°µµ Á¦Ç°ÀÔ´Ï´Ù. |
1/EA | ¼ÒºñÀÚ°¡ : 3,003,300¿ø |
30 Day | °ü½É |
| B04-91-530 | LC-LT422 |  Low Temp. Bath Circulating 22L, -40¡É ¡Ú ¹è¼Ûºñ º°µµ Á¦Ç°ÀÔ´Ï´Ù. |
1/EA | ¼ÒºñÀÚ°¡ : 3,356,300¿ø |
5 | °ü½É |
| B04-91-540 | LC-LT430 |  Low Temp. Bath Circulating 30L, -40¡É ¡Ú ¹è¼Ûºñ º°µµ Á¦Ç°ÀÔ´Ï´Ù. |
1/EA | ¼ÒºñÀÚ°¡ : 3,513,100¿ø |
1 | °ü½É |
Validation Service (Áö¿ªÀ̳ª °í°´ ¿äû¿¡ ÀÇÇÏ¿© ºñ¿ëÀÌ º¯°æµÉ ¼ö ÀÖÀ½) |
||||||
| Cat. No | Model | Description | Unit | Price(VATº°µµ) | Àç°í/³³±â | ºñ°í |
| B04-91-992 | VA-LCWB100 |  Qualification IQ, OQ for Low Temp. Circulating Water Bath | 1/EA | ¹®ÀÇ |
998 | °ü½É |
| B04-91-892 | VA-LCWB200 |  Qualification PQ for Low Temp. Circulating Water Bath | 1/EA | ¹®ÀÇ |
30 Day | °ü½É |
Optional Accessory |
||||||
| Cat. No | Model | Description | Unit | Price(VATº°µµ) | Àç°í/³³±â | ºñ°í |
| B04-01-085 | LI-USB |  RS485 to USB Communication Cable | 1/EA | ¼ÒºñÀÚ°¡ : 134,100¿ø |
1 | °ü½É |
| B04-91-483 | ET101M |  ¿ÜºÎ¼¾¼ Pt100/4xL300mm/Cable 2m ¼ÕÀâÀÌ | 1/EA | ¼ÒºñÀÚ°¡ : 86,000¿ø |
11 | °ü½É |